Overhead conductors
ACSR Conductor — Aluminium Conductor Steel Reinforced
Wolf, Dog, Zebra and more — stranded to IEC, BS, ASTM and GB.
- Cross-section
- 16 – 1,000 mm²
- Rated voltage
- LV – 500 kV lines
- Standard
- IEC 61089
Bare overhead conductor with hard-drawn aluminium wires stranded around a galvanised steel core, from 16 to 1,000 mm². The steel core carries the tension, the aluminium carries the current. Greased and aluminium-clad steel versions for coastal and polluted areas.
ModelsACSR WolfACSR ZebraJL/G1A 240/30
- IEC 61089
- BS 215-2
- ASTM B232
- GB/T 1179
Highlights
- 16 – 1,000 mm² aluminium area
- BS 215, IEC 61089, ASTM B232, GB/T 1179
- Galvanised or aluminium-clad steel core
- Drum lengths per span plan
Technical data
| Model | ACSR Wolf | ACSR Zebra | JL/G1A 240/30 |
|---|---|---|---|
| Conductor | Hard-drawn aluminium 1350-H19 wires around a galvanised steel core | ||
| Construction | Concentric-lay, 6/1 to 54/19 stranding | ||
| Cross-section | 16 – 1,000 mm² aluminium area | ||
| Steel core | Class A galvanised steel; class B, aluminium-clad (ACS) or high-strength on request | ||
| Corrosion protection | Neutral grease on steel core or inner layers on request (marine and polluted areas) | ||
| Application | Transmission and distribution overhead lines, substation busbars | ||
| Packaging | Steel or wooden drums, lengths per span plan | ||
| Standard | IEC 61089, BS 215-2, ASTM B232, GB/T 1179 | ||
ACSR code sizes (BS 215 / IEC 61089)
| Code name | Aluminium wiresn/mm | Steel wiresn/mm | Aluminium areamm² | Total areamm² | Outer diameter≈mm | Approx. weight≈kg/km | Rated tensile strengthkN | Max. DC resistance20 °CΩ/km |
|---|---|---|---|---|---|---|---|---|
| Rabbit | 6/3.35 | 1/3.35 | 52.9 | 61.7 | 10.05 | 214 | 18.4 | 0.5426 |
| Dog | 6/4.72 | 7/1.57 | 105.0 | 118.5 | 14.15 | 394 | 32.7 | 0.2733 |
| Wolf | 30/2.59 | 7/2.59 | 158.1 | 194.9 | 18.13 | 726 | 69.2 | 0.1828 |
| Lynx | 30/2.79 | 7/2.79 | 183.4 | 226.2 | 19.53 | 842 | 79.8 | 0.1576 |
| Panther | 30/3.00 | 7/3.00 | 212.1 | 261.6 | 21.00 | 974 | 89.7 | 0.1363 |
| Zebra | 54/3.18 | 7/3.18 | 428.9 | 484.5 | 28.62 | 1,621 | 131.9 | 0.0674 |
| Moose | 54/3.53 | 7/3.53 | 528.5 | 597.0 | 31.77 | 1,998 | 159.6 | 0.0547 |
Standard reference values from the conductor standards; other code sizes (ASTM, DIN, GB) on request.
Related products
Overhead conductorsAAAC Conductor — All-Aluminium Alloy
AAAC 6201 150 mm²
- Cross-section
- 16 – 800 mm²
- Rated voltage
- LV – 220 kV lines
- Standard
- IEC 61089
Overhead conductorsAerial Bundled Cable (ABC) 0.6/1 kV
NFC 33-209 3×70+54.6
- Cross-section
- 2 × 16 – 3 × 150 + 70
- Rated voltage
- 0.6/1 kV
- Standard
- NF C 33-209
Made in our plant
MV & HV power cablesSingle-Core MV XLPE Cable 6/10 – 26/35 kV (Cu / Al)
N2XSY 1×240/25 18/30 kV
- Cross-section
- 35 – 630 mm²
- Rated voltage
- 3.6/6 – 26/35 kV
- Standard
- IEC 60502-2
Inquire about this cable
ACSR Conductor — Aluminium Conductor Steel Reinforced
Typical reply within one working day.