Inside the Xinya cable plant

Wire drawing, stranding, triple extrusion, armouring and high-voltage testing under one roof.

01

Utility cable makers

Xinya Power Cables started with distribution cables for power utilities. Today the plant makes the whole range — from building wire and control cables to medium- and high-voltage XLPE and overhead conductors.

02

Process in our own hands

Copper and aluminium rod is drawn, stranded and compacted in-house; MV and HV cores are triple-extruded and dry-cured on a catenary line; armouring, sheathing and testing follow on the same site.

03

Engineers who answer

Our engineers check ratings, voltage drop and short-circuit capacity, prepare cable schedules and drum plans, and answer in 13 languages.

132 kVhighest XLPE voltage class
1,600 mm²largest conductor cross-section
40+export countries
100 %of MV and HV lengths PD-tested

What we commit to

  • Honest data sheets: real conductor resistance, real insulation thickness
  • Full length on every drum, metered on the line
  • Routine test report with every shipment
  • Fast, documented quotations — within one working day

How it is made

Rod in, drums out.

Six steps decide whether a power cable lasts decades in service. All six happen on our site.

  1. Wire drawing — copper and aluminium rod to fine wire
    01 / 06Wire drawing — copper and aluminium rod to fine wire
  2. Stranding and compacting conductors
    02 / 06Stranding and compacting conductors
  3. Triple extrusion on the catenary CCV line
    03 / 06Triple extrusion on the catenary CCV line
  4. Steel wire and tape armouring
    04 / 06Steel wire and tape armouring
  5. High-voltage and partial-discharge testing
    05 / 06High-voltage and partial-discharge testing
  6. Drum winding, lagging and dispatch
    06 / 06Drum winding, lagging and dispatch

Testing

Every drum leaves with a test report.

Routine tests on every production length, sample tests on every batch and type tests to the product standard.

High-voltage test hallHigh-voltage test hall

Routine tests on every length

  • 01Conductor DC resistance at 20 °C
  • 02AC voltage test (3.5 U₀ for MV, 5 min)
  • 03Partial discharge measurement (MV and HV)
  • 04Spark test on sheath
  • 05Insulation resistance
  • 06Dimensions, eccentricity and marking

Sample tests on every batch

  • 01Hot-set test of XLPE
  • 02Insulation and sheath thickness
  • 03Tensile strength and elongation
  • 04Flame test IEC 60332-1-2

Test reports and certificate copies are sent with your quotation — ask for the documents your project requires. Third-party inspection is welcome.

Standards we build to

  • IEC 60502-1
  • IEC 60502-2
  • IEC 60840
  • IEC 60228
  • IEC 61089
  • IEC 60331
  • IEC 60332-3
  • IEC 60754
  • IEC 61034
  • BS 5467
  • BS 6724
  • BS 7846
  • BS 5308
  • BS 6387
  • EN 50525
  • EN 50182
  • NF C 33-209
  • UL 83
  • GB/T 12706

From inquiry to delivery

A clear path, with an engineer — not a script — at every step.

  1. 01Inquiry

    Send cable types, sizes and lengths. Reply within one working day.

  2. 02Engineering

    Rating and voltage-drop check, cable schedule, drum plan.

  3. 03Production

    Drawing, stranding, extrusion, armouring — with progress photos.

  4. 04Testing

    Routine tests on every length; witness and third-party inspection welcome.

  5. 05Delivery

    Steel or wooden drums, lagged and marked; documents per project.

Send us your cable schedule.

Types, sizes, lengths and destination are enough. An engineer replies with a checked selection, drum plan and quotation within one working day.