Overhead conductors
AAAC Conductor — All-Aluminium Alloy
No steel to corrode — stronger and lighter lines near the coast.
- Cross-section
- 16 – 800 mm²
- Rated voltage
- LV – 220 kV lines
- Standard
- IEC 61089
Overhead conductor stranded from heat-treated aluminium-magnesium-silicon alloy wires. Higher strength than pure aluminium and no galvanic corrosion between steel and aluminium, so it lasts longer in coastal and industrial air and allows longer spans than AAC.
ModelsAAAC 6201 150 mm²JLHA1 185ASTM B399
- IEC 61089
- EN 50182
- ASTM B399
- GB/T 1179
Highlights
- 16 – 800 mm², 7 – 61 wires
- AlMgSi 6201-T81 alloy
- No steel core to corrode
- IEC 61089, EN 50182, ASTM B399
Technical data
| Model | AAAC 6201 150 mm² | JLHA1 185 | ASTM B399 |
|---|---|---|---|
| Conductor | Aluminium-magnesium-silicon alloy 6201-T81 (AlMgSi) wires | ||
| Construction | Concentric-lay, 7 to 61 wires | ||
| Cross-section | 16 – 800 mm² | ||
| Application | Distribution and transmission lines in coastal and industrial areas: no steel core to corrode, lighter than ACSR | ||
| Packaging | Steel or wooden drums | ||
| Standard | IEC 61089, EN 50182, ASTM B399 | ||
AAAC standard sizes
| Cross-sectionmm² | Strandingn/mm | Total areamm² | Outer diameter≈mm | Approx. weight≈kg/km | Rated tensile strengthkN | Max. DC resistance20 °CΩ/km |
|---|---|---|---|---|---|---|
| 35 | 7/2.52 | 34.9 | 7.56 | 95 | 10.3 | 0.952 |
| 50 | 7/3.00 | 49.5 | 9.00 | 136 | 14.6 | 0.672 |
| 70 | 7/3.55 | 69.3 | 10.65 | 190 | 20.4 | 0.480 |
| 95 | 19/2.50 | 93.3 | 12.50 | 256 | 27.5 | 0.357 |
| 120 | 19/2.85 | 121.2 | 14.25 | 333 | 35.8 | 0.275 |
| 150 | 19/3.15 | 148.1 | 15.75 | 407 | 43.7 | 0.225 |
| 185 | 37/2.50 | 181.6 | 17.50 | 500 | 53.6 | 0.184 |
| 240 | 37/2.85 | 236.0 | 19.95 | 650 | 69.6 | 0.141 |
| 300 | 37/3.20 | 297.6 | 22.40 | 820 | 87.8 | 0.112 |
Standard reference values from the conductor standards; other code sizes (ASTM, DIN, GB) on request.
Related products
Made in our plant
Overhead conductorsACSR Conductor — Aluminium Conductor Steel Reinforced
ACSR Wolf
- Cross-section
- 16 – 1,000 mm²
- Rated voltage
- LV – 500 kV lines
- Standard
- IEC 61089
Overhead conductorsAerial Bundled Cable (ABC) 0.6/1 kV
NFC 33-209 3×70+54.6
- Cross-section
- 2 × 16 – 3 × 150 + 70
- Rated voltage
- 0.6/1 kV
- Standard
- NF C 33-209
Made in our plant
MV & HV power cablesSingle-Core MV XLPE Cable 6/10 – 26/35 kV (Cu / Al)
N2XSY 1×240/25 18/30 kV
- Cross-section
- 35 – 630 mm²
- Rated voltage
- 3.6/6 – 26/35 kV
- Standard
- IEC 60502-2
Inquire about this cable
AAAC Conductor — All-Aluminium Alloy
Typical reply within one working day.