LV power cables
0.6/1 kV Aluminium XLPE Power Cable
Large feeders at a lower cost and weight per metre.
- Cross-section
- 16 – 630 mm²
- Rated voltage
- 0.6/1 kV
- Standard
- IEC 60502-1
Low-voltage power cable with compacted aluminium (or AA-8000 alloy) conductors, XLPE insulation and PVC or PE sheath, unarmoured or armoured. For distribution networks, sub-mains and long feeders where aluminium cuts cable cost and weight compared with copper.
ModelsNA2XY 4×150AL/XLPE/PVC 3×185+95YJLV / YJLV22
- IEC 60502-1
- IEC 60228
- GB/T 12706.1
Highlights
- 1 – 5 cores, 16 – 630 mm²
- About half the weight of copper
- Unarmoured, STA or SWA
- Compatible with Al / bimetal lugs
Technical data
| Model | NA2XY 4×150 | AL/XLPE/PVC 3×185+95 | YJLV / YJLV22 |
|---|---|---|---|
| Rated voltage | 0.6/1 kV | ||
| Conductor | Aluminium, class 2, compacted circular or sector-shaped; AA-8000 alloy on request | ||
| Cross-section | 1 – 5 cores, 16 – 630 mm² | ||
| Insulation | XLPE | ||
| Armour | Unarmoured, steel tape (STA) or steel wire (SWA) | ||
| Outer sheath | PVC (ST2), black; PE for direct burial | ||
| Operating temperature | 90 °C continuous conductor temperature | ||
| Short-circuit temperature | 250 °C, 5 s | ||
| Flame retardancy | Flame retardant, IEC 60332-1-2 | ||
| Application | Feeders, distribution networks and large sub-mains where weight and cost per metre matter | ||
| Packaging | Drums of 500 – 1,000 m | ||
| Standard | IEC 60502-1, GB/T 12706.1 | ||
0.6/1 kV four-core aluminium XLPE — construction & ratings
| Cross-sectionmm² | Outer diameter≈mm | Approx. weight≈kg/km | Max. DC resistance20 °CΩ/km | Current rating, in airA |
|---|---|---|---|---|
| 4 × 16 | 21 | 560 | 1.91 | 78 |
| 4 × 25 | 24 | 760 | 1.2 | 98 |
| 4 × 35 | 26 | 940 | 0.868 | 122 |
| 4 × 50 | 28 | 1,100 | 0.641 | 149 |
| 4 × 70 | 32 | 1,450 | 0.443 | 192 |
| 4 × 95 | 36 | 1,850 | 0.32 | 235 |
| 4 × 120 | 40 | 2,250 | 0.253 | 273 |
| 4 × 150 | 44 | 2,700 | 0.206 | 316 |
| 4 × 185 | 49 | 3,300 | 0.164 | 363 |
| 4 × 240 | 55 | 4,150 | 0.125 | 430 |
| 4 × 300 | 60 | 5,050 | 0.1 | 497 |
Standard reference values: conductor resistance per IEC 60228 class 2, current ratings indicative (IEC 60364-5-52 method E, 30 °C). Non-standard designs on request.
Related products
Made in our plant
LV power cables0.6/1 kV XLPE Copper Power Cable (CU/XLPE/PVC)
CU/XLPE/PVC 4×95
- Cross-section
- 1.5 – 630 mm²
- Rated voltage
- 0.6/1 kV
- Standard
- IEC 60502-1
Made in our plant
LV power cablesSWA Armoured Cable BS 5467, 600/1000 V
BS 5467 4C×35 SWA
- Cross-section
- 1.5 – 400 mm²
- Rated voltage
- 0.6/1 kV
- Standard
- BS 5467
Made in our plant
MV & HV power cablesSingle-Core MV XLPE Cable 6/10 – 26/35 kV (Cu / Al)
N2XSY 1×240/25 18/30 kV
- Cross-section
- 35 – 630 mm²
- Rated voltage
- 3.6/6 – 26/35 kV
- Standard
- IEC 60502-2
Inquire about this cable
0.6/1 kV Aluminium XLPE Power Cable
Typical reply within one working day.