Building wires & flexible cables
Building Wire H07V-U / H07V-R / H07V-K
Single-core PVC wires for every distribution board and conduit.
- Cross-section
- 1.5 – 400 mm²
- Rated voltage
- 450/750 V
- Standard
- EN 50525-2-31
Single-core PVC-insulated building wire to EN 50525-2-31 and IEC 60227-3: solid (-U), stranded (-R) or flexible (-K) copper, 450/750 V, flame retardant. Packed in 100 m coils with your label — for distributors, contractors and panel builders.
ModelsH07V-U 1.5 – 10H07V-R 6 – 400H07V-K / BV / BVR
- EN 50525-2-31
- IEC 60227-3
- IEC 60332-1-2
- GB/T 5023
Highlights
- 1.5 – 400 mm², 450/750 V
- Solid, stranded or flexible
- 7 standard colours
- Private-label coils and cartons
Technical data
| Model | H07V-U 1.5 – 10 | H07V-R 6 – 400 | H07V-K / BV / BVR |
|---|---|---|---|
| Rated voltage | 450/750 V | ||
| Conductor | Plain copper: class 1 solid (-U), class 2 stranded (-R), class 5 flexible (-K) | ||
| Cross-section | 1.5 – 400 mm² | ||
| Insulation | PVC type TI1 / TI3 (heat resistant to 90 °C on request) | ||
| Colour | Brown, blue, black, grey, red, white, green-yellow | ||
| Operating temperature | 70 °C continuous conductor temperature (PVC) | ||
| Flame retardancy | Flame retardant, IEC 60332-1-2 | ||
| Application | Fixed wiring in conduit and trunking, switchboards and distribution boards | ||
| Packaging | 100 m coils in shrink film or cartons; drums for large sizes | ||
| Standard | EN 50525-2-31, IEC 60227-3, GB/T 5023 | ||
H07V-R single-core — construction & ratings
| Cross-sectionmm² | Insulation thicknessmm | Outer diameter≈mm | Approx. weight≈kg/km | Max. DC resistance20 °CΩ/km | Current rating, in conduitA |
|---|---|---|---|---|---|
| 1.5 | 0.7 | 3.0 | 20 | 12.1 | 17.5 |
| 2.5 | 0.8 | 3.6 | 31 | 7.41 | 24 |
| 4 | 0.8 | 4.2 | 46 | 4.61 | 32 |
| 6 | 0.8 | 4.8 | 65 | 3.08 | 41 |
| 10 | 1.0 | 6.1 | 112 | 1.83 | 57 |
| 16 | 1.0 | 7.0 | 168 | 1.15 | 76 |
| 25 | 1.2 | 8.8 | 270 | 0.727 | 101 |
| 35 | 1.2 | 10.0 | 365 | 0.524 | 125 |
| 50 | 1.4 | 11.8 | 500 | 0.387 | 151 |
| 70 | 1.4 | 13.6 | 700 | 0.268 | 192 |
| 95 | 1.6 | 15.8 | 950 | 0.193 | 232 |
| 120 | 1.6 | 17.4 | 1,180 | 0.153 | 269 |
Standard reference values: current ratings per IEC 60364-5-52 (single circuit, 30 °C air / 20 °C soil, no grouping); dimensions and weights are typical. Non-standard designs on request.
Related products
Building wires & flexible cablesTHHN / THWN-2 Building Wire, UL 83
THHN/THWN-2 12 AWG
- Cross-section
- 14 AWG – 1,000 kcmil
- Rated voltage
- 600 V
- Standard
- UL 83
Building wires & flexible cablesRubber Flexible Cable H07RN-F
H07RN-F 3G2.5
- Cross-section
- 1 – 400 mm²
- Rated voltage
- 450/750 V
- Standard
- EN 50525-2-21
Made in our plant
MV & HV power cablesSingle-Core MV XLPE Cable 6/10 – 26/35 kV (Cu / Al)
N2XSY 1×240/25 18/30 kV
- Cross-section
- 35 – 630 mm²
- Rated voltage
- 3.6/6 – 26/35 kV
- Standard
- IEC 60502-2
Inquire about this cable
Building Wire H07V-U / H07V-R / H07V-K
Typical reply within one working day.